Feasibility of Low-Seated Composite Aortic Conduit for Surgical Treatment of Prosthetic Valve Endocarditis: A Case Report

Feasibility of Low-Seated Composite Aortic Conduit for Surgical Treatment of Prosthetic Valve Endocarditis: A Case Report

Author Info

Corresponding Author
Christopher K. Mehta
Division of Cardiac Surgery, Department of Surgery, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA

A B S T R A C T

Background: A 49-year-old male presented with a delayed diagnosis of infective endocarditis leading to extensive intracardiac destruction. Such cases present technical challenges to operative debridement as crucial anchoring points for replacement conduits are compromised. Case Presentation: Our patient presented at age 49 with nausea, lethargy, and diarrhea 2 weeks after recent travel. His prior history included bioprosthetic valve replacement for a bicuspid aortic valve. The patient was first given a trial of antimicrobials for a suspected UTI. Subsequently, he was admitted briefly to an outside hospital for a “cardiac work-up,” which returned negative. The patient sought care for the third time, during which he developed unstable supraventricular tachycardia, prompting echocardiography 16 days following the onset of symptoms. Echocardiography demonstrated a 6 cm abscess cavity invading the interventricular septum with a fistula into the left ventricular outflow tract, multiple ventricular septal defects (VSD), and suspected fistulae into the right ventricular outflow tract. The patient was treated with valve explant and extensive debridement. A valved-conduit for the aorta could not be sewn to the aortic annulus in the usual fashion due to destruction and debridement of the annulus, so a neo-annulus was created using the anterior leaflet of the mitral valve and the left ventricular outflow tract of the heart below the level of the VSDs. A mechanical-valved conduit was implanted onto the neo-annulus. A pacemaker was subsequently implanted. Conclusion: In patients with extensive intracardiac destruction with the compromise of the aortic annulus due to infective endocarditis, a low-seated, mechanical-valved conduit implanted directly to the aorto-mitral curtain and left ventricular outflow tract should be considered a novel, durable reconstructive option that allows complete debridement of infected tissues.

Article Info

Article Type
Case Report
Publication history
Received: Sat 09, Jul 2022
Accepted: Tue 02, Aug 2022
Published: Mon 12, Sep 2022
Copyright
© 2023 Christopher K. Mehta. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Hosting by Science Repository.
DOI: 10.31487/j.JSCR.2022.02.01