TY - JOUR AR - JSO-2018-1-103 TI - Biomechanical Study of Simulated Metastatic Peri-Acetabular Defects AU - Francis R. , Patterson AU - Jennifer , Thomson AU - Joseph, Benevenia AU - Kathleen S. , Beebe AU - Michael N. , Kang JO - Journal of Surgical Oncology PY - 2018 DA - Sat 29, Dec 2018 SN - 2674-3000 DO - http://dx.doi.org/10.31487/j.JSO.2018.01.003 UR - https://www.sciencerepository.org/biomechanical-study-of-simulated-metastatic-peri-acetabular-defects_JSO-1-103 KW - Peri-acetabular, Harrington, biomechanical AB - Peri-acetabular metastasis presents the risk of fracture. However, the relationship between bone loss and fracture risk is unknown. Utilizing fresh frozen intact cadaver pelves, Harrington class I lesions were simulated. Lesions were categorized as small (<40%) or large (>40%) Axial loading was applied in a quasistatic mechanism by a mechanical testing system to catastrophic failure, with the load-to-failure force being measured. There was statistical difference in the load-to-failure force between hemi-pelves with large defects and their matched controls. It was found that mean load-to-failure strength of a hemi-pelvis with a Class I defect was more than 2.3-2.45 times the calculated hip joint reactive force. Thus, it was concluded that a pelvis with a peri-acetabular defect of greater than 40% has a significantly lower load-to-failure strength compared to an intact pelvis. However, even this large Class I defect will fracture only at supraphysiologic loads and the hip joint may not normally be exposed to forces that high.